Lightning rod-YBT-YFD68

YBT-YFD68 Active pre-discharge lightning rod

                                                       2fff9d67 4032 438d 8614 10e13613c6af

 

 

Model:YBT-YFD68 Active Early Streamer Emission (ESE)Lightning Rod

Early Streamer Emission Time:68 μs

Material:Alloy

Weight:4kg

Installation Method:Flange fixation/Welding

Operating Conditions:Work all day

Corrosion Resistance:Highly corrosion-resistant,acid and alkali-proof

Appearance:Sleek design,easy to install

Maintenance-Free:Passive operation,no power supply required,no energyconsuming components

ESE Function:Equipped with energy storage components capable of triggering upward leaders;optimized tip radius to reduce corona effect and ensure proper functioning of the pulse device

Lightning Rod Features

Strictly follow the mandatory provisions of the National Lightning Protection Standard of the People’s Republic of China -“Code for Lightning Protection Design of Buildings”(GB50057 -2010).

The electronic components are completely wrapped in epoxy resin to prevent the internal electronic components from being damaged by lightning.

No radioactive elements,safe and reliable;stainless steel material,corrosionresistant,beautiful appearance.

Accurately judge the discharge timing to make lightning strike more accurate and reduce

the probability of lightning striking points not falling on the lightning rod body. A fully active system that activates itself only when there is a sign of lightning.

Calculation method of protected area

YBT-YFD68 active pre-discharge lightning rod protection radius Rp protection radius calculation formula:According to NFC17 -102,the tip of the lightning rod should be more than 2M above the horizontal plane of the protected object.When the relative installation height h of the lightning rod is different,its protection radius Rp follows the following calculation formula:Rp=√h(2D-h)+△L(2D+△L)

The calculation formula should take into account the lightning protection level of the protected object,local thunderstorm activities,and geological features.The protection radius Rp of the lightning rod is related to the height h, the preemptive start time,the lightning rod model,and the selected protection level.Among them:Rp is the protection radius of a lightning rod at a certain height.

The above formula is applicable to h>5m;when h<5m,the

corresponding protection radius of each model can be found from Table 1.1 :

①h is the actual height from the top of the YBT-YFD68 active pre-discharge lightning rod to the protected plane.

②D is the electric shock distance or rolling ball radius,which depends on the protection level of the protected object.For

Class 1,Class Ⅱ,and Class Ⅲprotection levels,the values of D are 20 meters,45 meters,and 60 meters respectively.The protection level determination of the protected object is shown in the NFCl7 -102 standard appendix.

③△L(m)=1(m/μs)×△T(μs).△T is the advance lead time,and its value is obtained by actual measurement of high-voltage experiments.

Quick reference table of protection radius of YBT-YFD68 active predischarge lightning rod in Class Ⅰ,Class Ⅱ,and Class Ⅲ:

3ad9c2aed0ca6c026ab240c941b248fd

Lightning rod installation

 

YBT-YFD68 active pre-discharge lightning rod strictly follows the mandatory provisions of the National Lightning Protection Standard of the People’s Republic of China -“Building Lightning Protection Design Code”(GB50057 -2010):

1.Determine the lightning protection category of the building according to the area,height,number of lightning days at the location,geographical environment correction coefficient,and building use nature of the protected building.

2.The down conductor (lower conductor)should be electrically connected to the main steel bars of the building,or two or more down conductors (lower conductors)should be made as required.

3.The down conductor (lower conductor)should be provided with a disconnect card and insulation protection on the nearby ground.

4.The grounding body,grounding resistor,and lightning protection ground network should be implemented in accordance with the requirements of the lightning protection standard GB50057 -2010.

Lightning rod installation diagram

 

wps图片(1)